Search

15 result(s)

Did you mean :

PET Alpha-Sy project - PhD fellows in Organic Chemistry / Radiopharmaceutical Chemistry (more information)
a training program PET-AlphaSy consisting in total 15 PhD students located in 5 European countries (Denmark, Sweden, Netherlands, Germany, Belgium). The PhD fellowships will attend common training sessions, e.g. within radiopharmaceutical chemistry or imaging and have secondments at the corresponding partner universities. The fellowships are available from 1 March 2019 or as soon as possible thereafter. More information can be found on https://www.alphasy.eu/. About PET-AlphaSY Our consortium has
/en/news/33_pet-alpha-sy-project-phd-fellows-in-organic-chemistry-radiopharmaceutical-chemistry-more-information

Hand-Foot-Cloth Monitor -
NUVIA - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - Our hand-, foot-, and cloths-monitor uses 2 scintillator materials. For detection of alpha-radiation, ZnS is applied, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like Am-241 or beta radiation like C-14.The thin window can be replaced easily by the user and measurements can be continued without delay. The
/en/cataloglight/hand-foot-cloth-monitor~f40c4fb6-37c5-4cdb-834d-9588b628b408

COMO 170 -
NUVIA - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - COMO is using 2 scintillator materials. For the detection of alpha-radiation ZnS is used, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like 238U, or beta radiation like 14C. The thin window can be replaced easily by the user and measurements can be continued without delay. The light flashes generated
/en/cataloglight/como-170~0851a77f-b02f-43bd-bccb-e4564de92b64

Genie 2000 -
Product & Services Software Spectroscopy Software - Genie 2000 is a comprehensive environment for data acquisition, display and analysis of gamma and alpha spectrometry data. It provides an intuitive and interactive human interface and comprehensive batch procedure capabilities. Through window screen management, graphical spectral display and analysis results can easily be positioned for quick comparisons.
/en/cataloglight/genie-2000~ee21b085-e67b-46bc-b26d-2d9c69b2b961

PAM-100 -
VF - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - A portable handheld device intended for the surface activity measurement of alpha, beta, and gamma radionuclides. Key Features Gasless scintillation detector... alpha and / or beta contamination. Models B and C are suitable for nuclear power plants, where the background from gamma radiation is increased variable. Monitor models D and E have increased gamma sensitivity.
/en/cataloglight/pam-100~335fbfed-1791-2210-fea9-3a09b9d24cb6

miniGITA Dual -
PET 😃😃😃😃😃 😃😃😃😃😃 No miniGITA 3SA probe SPECT & PET 😃 😃😃😃 😃😃😃😃😃 No miniGITA Alpha probe Alpha 😃😃😃😃 😃😃😃 ----- No miniGITA OFA (One fits all) probe: The One Fits All is based on our V-Shaped BGO technology. The crystal allows you... several other Elysia instruments. Built-in high quality PMT is the best choice for spectrum analysis and nucleic identification. miniGITA Alpha probe: The miniGITA Alpha probe has been designed to provide optimal alpha sensitivity when combined with our
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

Inspector -
Product & Services Instruments Environment radiation control - INSPECTOR is a simple, universal, hand-held radioactivity detector, sensitive for alpha, beta, gamma and x-ray radiation. INSPECTOR has a large end-window Geiger-Mueller counting tube with a window diameter of 45 mm. INSPECTOR has an optical and acoustical event indicator. INSPECTOR can be used as ratemeter or scaler/timer for momentary or long-term measurements. INSPECTOR can display activity in total counts (accumulated in time
/en/cataloglight/inspector~24204c2f-8cd1-497d-90b7-ad02f3f59bb7

MALISA Star -
Elysia - Products & Software Instruments Other instruments - MANUAL LIQUID SCINTILLATION COUNTER MALISA Star is a manual liquid scintillation counter specially designed for α and β- radioactivity detection in a liquid scintillator. MALISA Star is equipped with dead time correction which enables very high count rates. Linear pulse summation improves the spectral resolution for precise separation of different energy spectra of various alpha, beta and gamma emitting nuclides. Low activity lead and
/en/cataloglight/malisa-star~fbc1c910-dcd8-7e93-1196-3a0e0d4a3092

PAM-170 -
contamination. Models of monitors A, B, C have suppressed gamma sensitivity. They are suitable where the user needs to properly distinguish alpha and / or beta contamination. Models B and C are suitable for nuclear power plants, where the background from
/en/cataloglight/pam-170~ecb4aaa3-3ccc-bcf0-79c9-3a09b9dc3cad

HF-4 -
VF - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - The HF-4 series hand-foot contamination monitors are intended for the measurement of surface contamination by alpha, beta and gamma emitting radionuclides on hands, feet, and clothing. Key Features Gas-less smart scintillation detectors Optimized number of detectors (two hands, two feet) Two-step measurement of hands (palms and backs) A detachable hand detector for frisking A variety of detectors available for
/en/cataloglight/hf-4~be277dd9-9b6a-526e-31ea-3a09b9f63ed0

MARITA Star -
words an entire TLC lane is imaged. The entrance window can be open for H-3-applications or closed for C-14 or any other beta- or beta+ radiation emitting nuclides. Thanks to its Open Window proportional counter it is also very sensitive to Alpha's. The imaging scanner uses a gas-filledproportional counter, which can detect all alpha, beta and gamma emitting isotopes. The system is equipped with Elysia-raytest LGC (low gas consumption) technology. Controlling the gas flow and consumption to
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

RITA -
be opened for H-3 and alpha applications or closed for C-14 or any other nuclide emitting beta- or beta + radiation. Many gamma-emitting nuclides also emit beta radiation. Pure gamma emitting nuclides can be detected as they produce Compton electrons. The Open window Proportional Gas Flow detector is very suited for low activity Alpha detection. RITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

miniGITA Single -
😃😃😃😃 😃😃😃 😃😃😃 Yes miniGITA PET probe PET 😃😃😃😃😃 😃😃😃😃😃 No miniGITA 3SA probe SPECT & PET 😃 😃😃😃 😃😃😃😃😃 No miniGITA Alpha probe Alpha 😃😃😃😃 😃😃😃 ----- No Probe types miniGITA OFA (One fits all) probe: The One Fits All is based on our V-Shaped.... miniGITA Alpha probe: The miniGITA Alpha probe has been designed to provide optimal alpha sensitivity when combined with our TLC scanner. The probe is based on a ZnS (Tl) scintillator connected to a PMT, combining high efficiency for alpha
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

PET-AlphaSy Project
Elysia-Raytest and the University of Liege are offering a three-year PhD fellowship in organic chemistry / radiopharmaceutical chemistry. The PhD fellowships are financed by the EU via an MC-ITN-ETN action. As such, the PhD fellowships are a part of a training program PET-AlphaSy consisting in total of 15 PhD students located in 5 European countries (Denmark, Sweden, Netherlands, Germany, Belgium). The PhD fellowships will attend common training sessions, e.g. within radiopharmaceutical
/en/news/30_pet-alphasy-project

PET-AlphaSy Project
Elysia-Raytest and the University of Liege are offering a three-year PhD fellowship in organic chemistry / radiopharmaceutical chemistry. The PhD fellowships are financed by the EU via an MC-ITN-ETN action. As such, the PhD fellowships are a part of a training program PET-AlphaSy consisting in total of 15 PhD students located in 5 European countries (Denmark, Sweden, Netherlands, Germany, Belgium). The PhD fellowships will attend common training sessions, e.g. within radiopharmaceutical
/en/news/29_pet-alphasy-project

Contact