Search

8 result(s)

Did you mean :

RAMONA Quattro -
screen. Each trace shows the same chromatogram slightly delayed. The individual fraction is flowing from the first to the second, third and fourth coincidence detector and is recorded individually. The flow time from the first to the second, third and fourth detector can be determined individually. Entering the individual flow delay from the first to the second, third and fourth detector to the recording program, 4 simultaneous chromatograms can be obtained and each trace delay can be adjusted
/en/cataloglight/ramona-quattro~9fcaacb6-60ae-4503-8eeb-e68c2c8e5db4

MARITA Star -
Products & Services Instruments Radio-TLC - MARITA Star – the single trace radioactivity thin-layer-chromatography detector – applies a linear analyser detector, which is sensitive over the entire chromatogram trace from start to finish, in other... radiation can be detected with high resolution using a narrow collimator window. MARITA Star can measure a single trace at once. The MARITAStar detector is elevated after the end of the measurement and a new chromatogram plate can be placed for the
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

Gabi * -
a particular nuclide. GABI* counts the radiation events in an energy channel per selected interval time. The information of counts per time is transferred to the GINA* program. The chromatogram is displayed live on screen. No overriding of ranges can
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

GITA* -
first 200 x 200 mm TLC plate are completed, the second TLC-plate can be scanned. A single chromatogram can be displayed live on the screen of the connected PC. Multiple traces can be displayed in 3-dimensional format. Peak integration and evaluation
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

PETra -
radiation events in an energy channel per selected interval time. Petra* has an extremely high dynamic range from 0 – 500.000 c/s. The information of counts per time unit is transferred to a PC running GINA* program and the chromatogram is displayed
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

RITA -
Products & Software Instruments Radio-TLC - RITA Star - the thin layer chromatography radioactivity detector - uses a linear analyzer detector, which is sensitive over the entire trace of the chromatogram from start to finish. The input window can be opened for H-3 and alpha applications or closed for C-14 or any other nuclide emitting beta- or beta + radiation. Many gamma-emitting nuclides also emit beta radiation. Pure gamma emitting nuclides can be detected as they produce Compton electrons
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

MiniGITA -
to the following trace and the next TLC can be examined. The chromatogram is displayed life on the screen of the connected PC. Peak integration and evaluation can be performed manually or automatically. The measurement and data handing is digital
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

Prep Probe -
interest based on chromatogram or defined signal threshold. The probes can be used in a Hot Cell combined with a HPLC or even in a synthesis unit . The long detector cable allows to use the GABI Nova outside of the Hot Cell and the probe inside the
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265

Contact