Gabi * -
a calibrated energy scale. Recalibration for compensation of any drift is easy, fast and fully automatic. GABI* has 2 simultaneous counting channels with 2 individually selectable energy thresholds each for setting an individual counting window for a particular nuclide. GABI* counts the radiation events in an energy channel per selected interval time. The information of counts per time is transferred to the GINA* program. The chromatogram is displayed live on screen. No overriding of ranges can
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

GITA* -
settings. For ɣ-nuclides, GITA* uses a scintillation probe with a BGO crystal. Due to its density, BGO has a quite high stopping power for radiation and a reasonable energy resolution. BGO is mechanically stable and non-hydroscopic. Relative small size and special shape enable a sophisticated design of the scintillation probe. There are 5 mechanical collimators designed for the energy ranges of 0-60, 60-150, 150-250, 250-450, >450 keV. Depending on the radiation energy of the radioactive compound, the
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

RAMONA Star -
. Photomultipliers with a 2” diameter photocathode have been selected for highest sensitivity and very low background. Liquid scintillation admixture is the most sensitive detection method for very low energy beta minus nuclides such as H-3. Alternative internal solid scintillators of suitable material and particle size offer the same efficiency for C-14 as liquid scintillator admixtures. Various internal solid scintillator materials and particle grades are recommended for low energy β- applications
/en/cataloglight/ramona-star~6f7c398c-84cb-4ec0-86c3-89dfe9431fe9

MUCHA Nova -
parameter selection and operation are performed by touching a soft key on the screen. Every screen offers all operational functions as needed for the analysis to be performed. Display of the measured spectrum is live. Periodic automatic energy... subtracted for the selected measurement time at selected regions. In order to offer a suitable spectrum display, a low, medium and high energy range can be selected. At the end of any measurement the spectrum can be printed or stored for further
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c

MiniGITA -
positron detector based on a small plastic scintillation probe. With this detector, the instrument can measure medium and high energy beta isotopes like 14[C], 90[Y], 18[F] 11[C] etc. The relative small size and fast respond time of the plastic scintillator allows to measure very high-count rates up to 500 000 cps and provides high sensitivity to positron emitters whilst significantly reducing background counts from non-positron emitting isotopes. For low energy y-nuclides like 99m[Tc] the positron
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

PETra -
a high voltage unit for manual or automatic selection of the required detector operation. Inserting a suitable calibration source and running the automatic calibration program, GABI* sets all parameters to a calibrated energy scale. Recalibration for compensation of any drift is quite easy, fast and fully automatic. Petra* has 2 simultaneous counting channels with 2 individually selectable energy thresholds, each for setting an individual counting window for a particular nuclide. Petra* counts the
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

Elysia nominated as Trends Gazelle 2021!
For 20 years now, the editors of Trends-Tendances and Trends have been selecting from 50 to 250 Trends Gazelles within each province. These growing companies are not only a source of energy for our economy but also a real inspiration for entrepreneurs. The title of Trends Gazelle is recognized in the business world because of its national reputation and regional recognition. The selection of Trends Gazelles is established on the basis of growth figures: - Growth in added value over the last 5
/en/news/62_elysia-nominated-as-trends-gazelle-2021

Elysia nominated as Trends Gazelle 2021!
For 20 years now, the editors of Trends-Tendances and Trends have been selecting from 50 to 250 Trends Gazelles within each province. These growing companies are not only a source of energy for our economy but also a real inspiration for entrepreneurs. The title of Trends Gazelle is recognized in the business world because of its national reputation and regional recognition. The selection of Trends Gazelles is established on the basis of growth figures: - Growth in added value over the last 5
/en/news/63_elysia-nominated-as-trends-gazelle-2021

MALISA Star -
Elysia - Products & Software Instruments Other instruments - MANUAL LIQUID SCINTILLATION COUNTER MALISA Star is a manual liquid scintillation counter specially designed for α and β- radioactivity detection in a liquid scintillator. MALISA Star is equipped with dead time correction which enables very high count rates. Linear pulse summation improves the spectral resolution for precise separation of different energy spectra of various alpha, beta and gamma emitting nuclides. Low activity lead and
/en/cataloglight/malisa-star~fbc1c910-dcd8-7e93-1196-3a0e0d4a3092

HPGe -
thickness of 0.5 mm and a 1 mm thick bottom. The ion implanted contact on the detector element is negligibly thin compared to 0.5 mm of aluminium so these detectors have intrinsically good low energy response, allowing spectroscopy down to 20 keV.Because
/en/cataloglight/hpge~f2f2ee0f-57b6-4e12-b924-51abd0272f73

Hand-Foot-Cloth Monitor -
NUVIA - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - Our hand-, foot-, and cloths-monitor uses 2 scintillator materials. For detection of alpha-radiation, ZnS is applied, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like Am-241 or beta radiation like C-14.The thin window can be replaced easily by the user and measurements can be continued without delay. The
/en/cataloglight/hand-foot-cloth-monitor~f40c4fb6-37c5-4cdb-834d-9588b628b408

COMO 170 -
NUVIA - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - COMO is using 2 scintillator materials. For the detection of alpha-radiation ZnS is used, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like 238U, or beta radiation like 14C. The thin window can be replaced easily by the user and measurements can be continued without delay. The light flashes generated
/en/cataloglight/como-170~0851a77f-b02f-43bd-bccb-e4564de92b64

RadFlash Dosimeter -
measurement accuracy: ± 15 % Energy range: 15 keV to 1.5 MeV
/en/cataloglight/radflash-dosimeter~e91be81b-a1f9-65eb-9eb8-3a09b9eeaab3

miniGITA Dual -
to detect SPECT and PET isotopes. The special V-shaped gives the best resolution without a compromise of sensitivity. A broad range of collimators allows you to adapt the probe to a larger energy band. The detector also has a multichannel function... range allowing you to use higher activities without signal saturation. A broad range of collimators allows the probe to be applied to a large energy range. miniGITA 3SA probe: The 3SA (Self Shielded Spectrum Analysis) probe for self-shielded spectrum
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

MARITA Star -
they produce some Compton electrons. MARITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is used for the electronic collimation. Thus, high energy beta
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

RITA -
used for the electronic collimation. Thus, high energy beta radiation can be detected with high resolution using a narrow collimator window. RITA Star is an extended version of MARITA that can measure automatically many single traces one after the
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

Prep Probe -
detector. This will ensure you a perfect documentation of your setup and enhance your GxP tools. The ECP advanced control and diagnostic of your probes ensure a better performance and a remote diagnostic. Model Energy range Application Probe PrepProbe
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265

miniGITA Single -
BGO technology. The crystal allows you to detect SPECT and PET isotopes. The special V-shaped gives the best resolution without a compromise of sensitivity. A broad range of collimators allows you to adapt the probe to a larger energy band. The
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

miniGITA Slim -
-Shaped BGO technology. The crystal allows you to detect SPECT and PET isotopes. The special V-shaped gives the best resolution without a compromise of sensitivity. A broad range of collimators allows you to adapt the probe to a larger energy band
/en/cataloglight/minigita-slim~18b8fe68-db1f-6195-d2d3-3a1cac5440b1