Search

15 result(s)

Did you mean :

PAM-100 -
VF - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - A portable handheld device intended for the surface activity measurement of alpha, beta, and gamma radionuclides. Key Features Gasless scintillation detector... PAM-100 series activity meters are portable hand-held instruments intended for the measurement of surface contamination. Models of monitors A, B, C have suppressed gamma sensitivity. They are suitable where the user needs to properly distinguish
/en/cataloglight/pam-100~335fbfed-1791-2210-fea9-3a09b9d24cb6

PAM-170 -
contamination. Models of monitors A, B, C have suppressed gamma sensitivity. They are suitable where the user needs to properly distinguish alpha and / or beta contamination. Models B and C are suitable for nuclear power plants, where the background from gamma radiation is increased variable. Monitor models D and E have increased gamma sensitivity.
/en/cataloglight/pam-170~ecb4aaa3-3ccc-bcf0-79c9-3a09b9dc3cad

Hand-Foot-Cloth Monitor -
NUVIA - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - Our hand-, foot-, and cloths-monitor uses 2 scintillator materials. For detection of alpha-radiation, ZnS is applied, for detection of beta and gamma radiation... light flashes generated by the alpha or beta/gamma radiation can be separated by pulse analysis. The detected events are counted over time and displayed digitally in c/s, Bq or Bq/cm2. Nuclide specific sensitivity is calculated and alarm values are
/en/cataloglight/hand-foot-cloth-monitor~f40c4fb6-37c5-4cdb-834d-9588b628b408

COMO 170 -
NUVIA - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - COMO is using 2 scintillator materials. For the detection of alpha-radiation ZnS is used, for detection of beta and gamma radiation a plastic scintillator foil... by the alpha or beta/gamma radiation can be separated by pulse analysis. The detected events are counted over time and displayed digitally in c/s, Bq or Bq/cm2. Nuclide specific sensitivity is calculated and alarm values are pre-programmed
/en/cataloglight/como-170~0851a77f-b02f-43bd-bccb-e4564de92b64

RadFlash Dosimeter -
Polimaster - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - X-ray and Gamma Radiation Personal Dosimeter PM1630 is a miniature electronic dosimeter capable of solving a wide range of personal dose monitoring tasks - measurement of personal dose equivalent (DE) and personal dose equivalent rate (DER) of X-ray (continuous and pulsed) and gamma radiation. The dosimeter also provides wireless on-line data transfer (DE and DER) and off-line transfer of instrument
/en/cataloglight/radflash-dosimeter~e91be81b-a1f9-65eb-9eb8-3a09b9eeaab3

MARITA Star -
. The imaging scanner uses a gas-filledproportional counter, which can detect all alpha, beta and gamma emitting isotopes. The system is equipped with Elysia-raytest LGC (low gas consumption) technology. Controlling the gas flow and consumption to achieve best measurement results with minimal gas consumption.Beta+ (PET) emitting nuclides are detected very efficiently. Many gamma radiation-emitting nuclides emit beta-radiation as well. The pure gamma emitting nuclides can be detected as well because
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

POMO Nova -
Products & Services Instruments Radio-Detectors - The POMO Nova is the latest member of our Radio-flow detector family for Beta +/- emitters for integration in our Radio-HPLC chain. Its high sensitivity for beta+ and Beta- particles makes it the detector of choice for your Radio pharmacy QC applications. Our high positron efficiency flow cells with low gamma response provide unique detection capabilities for PET isotope studies and ensure low background noise. The POMO Nova is perfectly suited
/en/cataloglight/pomo-nova~06542afd-f178-4836-a588-f92658b81670

MALISA Star -
Elysia - Products & Software Instruments Other instruments - MANUAL LIQUID SCINTILLATION COUNTER MALISA Star is a manual liquid scintillation counter specially designed for α and β- radioactivity detection in a liquid scintillator. MALISA Star is equipped with dead time correction which enables very high count rates. Linear pulse summation improves the spectral resolution for precise separation of different energy spectra of various alpha, beta and gamma emitting nuclides. Low activity lead and
/en/cataloglight/malisa-star~fbc1c910-dcd8-7e93-1196-3a0e0d4a3092

HF-4 -
VF - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - The HF-4 series hand-foot contamination monitors are intended for the measurement of surface contamination by alpha, beta and gamma emitting radionuclides on hands, feet, and clothing. Key Features Gas-less smart scintillation detectors Optimized number of detectors (two hands, two feet) Two-step measurement of hands (palms and backs) A detachable hand detector for frisking A variety of detectors available for
/en/cataloglight/hf-4~be277dd9-9b6a-526e-31ea-3a09b9f63ed0

RITA -
Products & Software Instruments Radio-TLC - RITA Star - the thin layer chromatography radioactivity detector - uses a linear analyzer detector, which is sensitive over the entire trace of the chromatogram from start to finish. The input window can be opened for H-3 and alpha applications or closed for C-14 or any other nuclide emitting beta- or beta + radiation. Many gamma-emitting nuclides also emit beta radiation. Pure gamma emitting nuclides can be detected as they produce Compton electrons
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

miniGITA Single -
miniGITA Single the perfect workhorse for your lab. Testing the radiochemical purity with thin layer chromatography and the execution of basic gamma spectrometry are a routine for many nuclear medicine laboratories and SPECT or PET facilities... sensitivity to positrons. High insensitivity to gamma radiation and an extremely high dynamic range ensure very low background noise to gamma irradiation and the possibility to handle high amounts of activity. These skills make the detector the right
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

MUCHA Nova -
Products & Software Instruments Multi Channel Analyser - MUCHA Nova is our multi-channel-analyser for ɣ-spectroscopy. The gamma radiation measuring system is designed for applications in nuclide laboratories for the determination of radio nuclide purity, for analysis of environmental samples or for determination of very low activities in food, water and waste samples. The operation of the multi-channel-analyser is simple and self-explanatory. The user is guided by dialog on the screen. The
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c

Gammadata, our new distributor for Scandinavia
For over four decades, they have been a trusted provider of expert services and high-quality instruments for radiation detection and material analysis. With this expertise and market knowledge, we are certain they will be a great help for our customers in that region.
/en/news/110_gammadata-our-new-distributor-for-scandinavia

miniGITA Dual -
basic gamma spectrometry are routine for most nuclear medicine laboratories and SPECT or PET facilities. A reliable, easy to use instrument, fulfilling the today standards in GMP and documentation rules is mandatory for optimal working. The dual head... TLC scanner. The probe is based on a ZnS (Tl) scintillator connected to a PMT, combining high efficiency for alpha radiation and low background for gamma. And the probe is also sensitive to beta- and Beta+ radiaton, than can be counted in a separate
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

GINA X -
management. Simply create different users with different user levels and decide about the rights of each user level. MCA - gamma spectroscopy module This module is needed to control our multi-channel Analyser (MUCHA). This modules allows to control the
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d

Contact