Did you mean :
COMO 170 -
NUVIA -
Radiation Protection Actif
Radiation Protection Hand-held
Radiation Monitoring - COMO is using 2 scintillator materials. For the detection of alpha-
radiation ZnS is used, for detection of beta and gamma
radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha
radiation like 238U, or beta
radiation like 14C. The thin window can be replaced easily by the user and measurements can be continued without delay. The light flashes generated
/en/cataloglight/como-170~0851a77f-b02f-43bd-bccb-e4564de92b64
Hand-Foot-Cloth Monitor -
NUVIA -
Radiation Protection Actif
Radiation Protection Hand and Foot monitoring - Our hand-, foot-, and cloths-monitor uses 2 scintillator materials. For detection of alpha-
radiation, ZnS is applied, for detection of beta and gamma
radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha
radiation like Am-241 or beta
radiation like C-14.The thin window can be replaced easily by the user and measurements can be continued without delay. The
/en/cataloglight/hand-foot-cloth-monitor~f40c4fb6-37c5-4cdb-834d-9588b628b408
RadFlash Dosimeter -
Polimaster -
Radiation Protection Actif
Radiation Protection Hand-held
Radiation Monitoring - X-ray and Gamma
Radiation Personal Dosimeter PM1630 is a miniature electronic dosimeter capable of solving a wide range of personal dose monitoring tasks - measurement of personal dose equivalent (DE) and personal dose equivalent rate (DER) of X-ray (continuous and pulsed) and gamma
radiation. The dosimeter also provides wireless on-line data transfer (DE and DER) and off-line transfer of instrument
/en/cataloglight/radflash-dosimeter~e91be81b-a1f9-65eb-9eb8-3a09b9eeaab3
PAM-170 -
VF -
Radiation Protection Actif
Radiation Protection Hand-held
Radiation Monitoring - Key Features Gasless scintillation detector Compact, lightweight and resistant design User friendly, ease of use High sensitivity, uniform response Fast selection... gamma
radiation is increased variable. Monitor models D and E have increased gamma sensitivity.
/en/cataloglight/pam-170~ecb4aaa3-3ccc-bcf0-79c9-3a09b9dc3cad
PAM-100 -
VF -
Radiation Protection Actif
Radiation Protection Hand-held
Radiation Monitoring - A portable handheld device intended for the surface activity measurement of alpha, beta, and gamma radionuclides. Key Features Gasless scintillation detector... alpha and / or beta contamination. Models B and C are suitable for nuclear power plants, where the background from gamma
radiation is increased variable. Monitor models D and E have increased gamma sensitivity.
/en/cataloglight/pam-100~335fbfed-1791-2210-fea9-3a09b9d24cb6
HF-4 -
VF -
Radiation Protection Actif
Radiation Protection Hand and Foot monitoring - The HF-4 series hand-foot contamination monitors are intended for the measurement of surface contamination by alpha, beta and gamma emitting radionuclides on hands, feet... optimum measurement of various
radiation types Dynamic processing algorithms to give shortest measurement times depending on background User friendly graphic interface Quick change of measurement parameters (for example alarm levels, nuclides, units) by
/en/cataloglight/hf-4~be277dd9-9b6a-526e-31ea-3a09b9f63ed0
Gammadata, our new distributor for Scandinavia
For over four decades, they have been a trusted provider of expert services and high-quality instruments for
radiation detection and material analysis. With this expertise and market knowledge, we are certain they will be a great help for our customers in that region.
/en/news/110_gammadata-our-new-distributor-for-scandinavia
MARITA Star -
words an entire TLC lane is imaged. The entrance window can be open for H-3-applications or closed for C-14 or any other beta- or beta+
radiation emitting nuclides. Thanks to its Open Window proportional counter it is also very sensitive to Alpha's... achieve best measurement results with minimal gas consumption.Beta+ (PET) emitting nuclides are detected very efficiently. Many gamma
radiation-emitting nuclides emit beta-
radiation as well. The pure gamma emitting nuclides can be detected as well because
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646
RITA -
be opened for H-3 and alpha applications or closed for C-14 or any other nuclide emitting beta- or beta +
radiation. Many gamma-emitting nuclides also emit beta
radiation. Pure gamma emitting nuclides can be detected as they produce Compton electrons... used for the electronic collimation. Thus, high energy beta
radiation can be detected with high resolution using a narrow collimator window. RITA Star is an extended version of MARITA that can measure automatically many single traces one after the
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb
Hot Cell for 18F -
Radioprotech -
Radiation Protection ELYSHIELD Bio Safety solutions - For F-18 applications a 50-mm lead shielding is not sufficient and our standard 68Ga Isolator is not suitable.Size, features and weight of an F-18 isolator are strongly depending on the specific needs of the customer. For this reason, we don’t propose a standard product.All products will be designed and manufactured according to the specific needs of your project.Please contact us and tell us a bit more about your needs. It
/en/cataloglight/hot-cell-for-18f~8e42ee55-7848-4823-9f6d-faf100efb9d2
GITA* -
settings. For ɣ-nuclides, GITA* uses a scintillation probe with a BGO crystal. Due to its density, BGO has a quite high stopping power for
radiation and a reasonable energy resolution. BGO is mechanically stable and non-hydroscopic. Relative small size and special shape enable a sophisticated design of the scintillation probe. There are 5 mechanical collimators designed for the energy ranges of 0-60, 60-150, 150-250, 250-450, >450 keV. Depending on the
radiation energy of the radioactive compound, the
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b
QC-Cubicle turn-key Lab Solution -
of eventual changes in regulations. Additional shielding and integrated waste-control significantly increase the
radiation protection compared to standard QC solutions. The large UPS ensures that the QC goes uninterrupted - even in the event of... workflows that guide users through lab processes and increase
radiation protection. We propose different QC-Cubicles optimized for dedicated radio pharmaceutics, however all of them can be extended with additional modules for the use of other tracers.
/en/cataloglight/qc-cubicle-turn-key-lab-solution~65e32b69-1286-4244-badc-327f4ff11677
AURAS -
radiotracers while allowing the adaptation of almost all analytical methods.It is an all-in-one solution with in-built shielding, along with an optional external shielded cover for unparalleled
radiation protection and measurement performance. The AURAS
/en/cataloglight/auras~ae7109a0-8076-68fe-4eb1-3a167f5a24bb
MUCHA Nova -
Products & Software Instruments Multi Channel Analyser - MUCHA Nova is our multi-channel-analyser for ɣ-spectroscopy. The gamma
radiation measuring system is designed for applications in nuclide laboratories for the determination of radio nuclide purity, for analysis of environmental samples or for determination of very low activities in food, water and waste samples. The operation of the multi-channel-analyser is simple and self-explanatory. The user is guided by dialog on the screen. The
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c
Prep Probe -
Products & Services Instruments Products & Services Instruments Radio-Detectors - Semi- and Preparative HPLC applications in radio-pharmaceutical synthesis are still a challenge in radio-detection. For most of the detectors, extremely high-count rates and
radiation result in limited dynamic range with low sensitivity for lower count rates or signal cut-offs with high count rates. Other challenges are the aging of the electronics caused by the strong irradiation and the size of the detector
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265
miniGITA Single -
radiation and low background gamma. And the probe is also sensitive to beta- and Beta+
radiaton, than can be counted in a separate beta window. Like all miniGITA probes, it uses ECP and can be used in combination with several other Elysia instruments... sensitivity to positrons. High insensitivity to gamma
radiation and an extremely high dynamic range ensure very low background noise to gamma irradiation and the possibility to handle high amounts of activity. These skills make the detector the right
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893