Clarity -
acquisition interfaces (A/D converters, LAN, USB, RS232) allows connection to any GC or LC chromatograph.Up to four independent chromatography systems can be simultaneously connected, each can acquire up to 32 signals.Control modules provide
/en/cataloglight/clarity~d510a4ad-a738-4fec-9583-29068b210979

RadFlash Dosimeter -
history events to radiation monitoring system database of different institutions. RadFlash is a perfect choice for healthcare professionals, radioisotope laboratories, security and customs officials.Thanks to its Bluetooth interface it can be connected
/en/cataloglight/radflash-dosimeter~e91be81b-a1f9-65eb-9eb8-3a09b9eeaab3

ECOS -
. The selection valve features 1/16” fittings with 0.40 mm port , the entry port is connected to tubing coming from injector and flow is automatically sent to the selected columns. The flow coming from the column is directed towards a manifold where the tubing going to detectors is connected (see scheme). Columns can be installed through standard 1/16” connectors and standard HPLC tubings (peek or stainless steel). The standard maximum pressure of the valve is 350 bars; higher pressure or an inert
/en/cataloglight/ecos~b6aebf6f-4fa1-a8d9-ee95-39e9890b29ad

Hot Cell for 68Ga -
synthesizers under a Class A environment.The Class B Ga-68 Generator pre-chamber is connected to the Class A working area through a multi-diameter sealing flange, allowing to connect up to 4 pipes. The chamber was designed to take up to 2
/en/cataloglight/hot-cell-for-68ga~50cc771e-12a2-45d9-8624-97be42b4d196

GITA* -
first 200 x 200 mm TLC plate are completed, the second TLC-plate can be scanned. A single chromatogram can be displayed live on the screen of the connected PC. Multiple traces can be displayed in 3-dimensional format. Peak integration and evaluation
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

Radio-HPLC -
based on Shimadzu or Agilent HPLC systems and we can deliver a complete line of detectors including UV, Refractive Index Detector (RID), Pulse Amperometric Detector (PAD) and Diode Array Detector (DAD).Elysia-Raytest devices can be connected to any
/en/cataloglight/radio-hplc~5531dd9b-67b0-43da-af76-9ac1a049665c

MiniGITA -
to the following trace and the next TLC can be examined. The chromatogram is displayed life on the screen of the connected PC. Peak integration and evaluation can be performed manually or automatically. The measurement and data handing is digital
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

miniGITA Dual -
TLC scanner. The probe is based on a ZnS (Tl) scintillator connected to a PMT, combining high efficiency for alpha radiation and low background for gamma. And the probe is also sensitive to beta- and Beta+ radiaton, than can be counted in a separate
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

miniGITA Single -
. miniGITA Alpha probe: The miniGITA Alpha probe has been designed to provide optimal alpha sensitivity when combined with our TLC scanner. The probe is based on a ZnS (Tl) scintillator connected to a PMT, combining high efficiency for alpha
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

GINA X -
evaluate older GINA Star data sets or to evaluate data sets generated with instruments controlled by GINA X. It allows you to use and work with GINA measurement files without the need of a connected ELYSIA-RAYTEST detector. It has all the features needed
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d