Search

17 result(s)

Did you mean :

POMO Nova -
Products & Services Instruments Radio-Detectors - The POMO Nova is the latest member of our Radio-flow detector family for Beta +/- emitters for integration in our Radio-HPLC chain. Its high sensitivity for beta+ and Beta- particles makes it the detector of choice for your Radio pharmacy QC applications. Our high positron efficiency flow cells with low gamma response provide unique detection capabilities for PET isotope studies and ensure low background noise. The POMO Nova is perfectly suited
/en/cataloglight/pomo-nova~06542afd-f178-4836-a588-f92658b81670

PET-Melt -
Product & Services Instruments Other instruments - Our Pet-melt is an ideal solution for the basic melting point testing. It is programmable and features a microprocessor-based control of oven temperature. The low volume 2mm diameter capillary tubes are ideal for radio-pharmaceutical applications.
/en/cataloglight/pet-melt~49468de1-09eb-49f6-81f0-83a3809350c5

HPGe -
thickness of 0.5 mm and a 1 mm thick bottom. The ion implanted contact on the detector element is negligibly thin compared to 0.5 mm of aluminium so these detectors have intrinsically good low energy response, allowing spectroscopy down to 20 keV.Because germanium has relatively low band gap, these detectors must be cooled in order to reduce the thermal generation of charge carriers.
/en/cataloglight/hpge~f2f2ee0f-57b6-4e12-b924-51abd0272f73

RAMONA Star -
. Photomultipliers with a 2” diameter photocathode have been selected for highest sensitivity and very low background. Liquid scintillation admixture is the most sensitive detection method for very low energy beta minus nuclides such as H-3. Alternative internal solid scintillators of suitable material and particle size offer the same efficiency for C-14 as liquid scintillator admixtures. Various internal solid scintillator materials and particle grades are recommended for low energy β- applications
/en/cataloglight/ramona-star~6f7c398c-84cb-4ec0-86c3-89dfe9431fe9

MALISA Star -
Elysia - Products & Software Instruments Other instruments - MANUAL LIQUID SCINTILLATION COUNTER MALISA Star is a manual liquid scintillation counter specially designed for α and β- radioactivity detection in a liquid scintillator. MALISA Star is equipped with dead time correction which enables very high count rates. Linear pulse summation improves the spectral resolution for precise separation of different energy spectra of various alpha, beta and gamma emitting nuclides. Low activity lead and
/en/cataloglight/malisa-star~fbc1c910-dcd8-7e93-1196-3a0e0d4a3092

MUCHA Nova -
purity, for analysis of environmental samples or for determination of very low activities in food, water and waste samples. The operation of the multi-channel-analyser is simple and self-explanatory. The user is guided by dialog on the screen. The... subtracted for the selected measurement time at selected regions. In order to offer a suitable spectrum display, a low, medium and high energy range can be selected. At the end of any measurement the spectrum can be printed or stored for further
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c

Hand-Foot-Cloth Monitor -
NUVIA - Radiation Protection Actif Radiation Protection Hand and Foot monitoring - Our hand-, foot-, and cloths-monitor uses 2 scintillator materials. For detection of alpha-radiation, ZnS is applied, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like Am-241 or beta radiation like C-14.The thin window can be replaced easily by the user and measurements can be continued without delay. The
/en/cataloglight/hand-foot-cloth-monitor~f40c4fb6-37c5-4cdb-834d-9588b628b408

COMO 170 -
NUVIA - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - COMO is using 2 scintillator materials. For the detection of alpha-radiation ZnS is used, for detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like 238U, or beta radiation like 14C. The thin window can be replaced easily by the user and measurements can be continued without delay. The light flashes generated
/en/cataloglight/como-170~0851a77f-b02f-43bd-bccb-e4564de92b64

MARITA Star -
. The imaging scanner uses a gas-filledproportional counter, which can detect all alpha, beta and gamma emitting isotopes. The system is equipped with Elysia-raytest LGC (low gas consumption) technology. Controlling the gas flow and consumption to... subsequent measurement. The counting gas is a non-inflammable mixture of 90% Argon and 10% Methane, which is traded as P10 gas. Gas consumption is very low. 1 TLC plate of 50 x 200 mm up to 200 x 200 mm can be placed on MARITA Star.
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

RITA -
. The Open window Proportional Gas Flow detector is very suited for low activity Alpha detection. RITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is... plate. The counting gas is a non-inflammable mixture of 90% Argon and 10% Methane, which is traded as P10 gas. The gas consumption is very low. 2 TLC plates of 200 x 200 mm each can be placed in RITA* at the same time. A metal/glass cover closes RITA
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

MIRA Star -
has been developed, using quite small photomultipliers with very low noise. The small photomultipliers are arranged in coincidence to obtain the best possible sensitivity. 4 coincidence detectors are arranged one after another. The very small
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba

AURAS -
Elysia - Products & Software Turn Key Packages AURAS Prep Module - AUTOMATE YOUR QUALITY CONTROL SIMPLE, INTUITIVE OPERATION FULLY COMPLIANT FLEXIBLE LOW RUNNING COSTS The AURAS concept is an Automated Radioactive Sample-handling module allowing you to upgrade your current quality control of radiopharmaceuticals. It is a new concept for the automated quality control of radiopharmaceuticals. AURAS has been designed to provide users with the flexibility they need for the analysis of many
/en/cataloglight/auras~ae7109a0-8076-68fe-4eb1-3a167f5a24bb

PETra -
. The special flow cell ensures that the sensitivity is high and the temperature of the scintillator is low.
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

miniGITA Single -
performance for every application. Our detectors work gas free, ensuring long life time and low maintenance costs. The high sensitivity combined to the moving sample table allows a very fast analysis, with an average scanning time of less than 1 minute. GxP... sensitivity to positrons. High insensitivity to gamma radiation and an extremely high dynamic range ensure very low background noise to gamma irradiation and the possibility to handle high amounts of activity. These skills make the detector the right
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

MiniGITA -
scintillator allows to measure very high-count rates up to 500 000 cps and provides high sensitivity to positron emitters whilst significantly reducing background counts from non-positron emitting isotopes. For low energy y-nuclides like 99m[Tc] the positron
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

Prep Probe -
Products & Services Instruments Products & Services Instruments Radio-Detectors - Semi- and Preparative HPLC applications in radio-pharmaceutical synthesis are still a challenge in radio-detection. For most of the detectors, extremely high-count rates and radiation result in limited dynamic range with low sensitivity for lower count rates or signal cut-offs with high count rates. Other challenges are the aging of the electronics caused by the strong irradiation and the size of the detector
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265

miniGITA Dual -
TLC scanner. The probe is based on a ZnS (Tl) scintillator connected to a PMT, combining high efficiency for alpha radiation and low background for gamma. And the probe is also sensitive to beta- and Beta+ radiaton, than can be counted in a separate
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

Contact