Did you mean :
RAPHAELA ACG -
radiopharmaceutical production and QC. It records
automatically and digitally the QC information from the different measurement instruments required by law for the release of a radio-pharmaceutical tracer. The software is preconfigured for 18F-FDG, but can also be easily used for other PET tracers like 18F-FEC, 18F-FET, etc. It can also collect data from the cyclotron, synthesis module, QC instruments & dispensing unit. It assembles
automatically all information to one common analysis report. This
/en/cataloglight/raphaela-acg~42aede2c-c39f-461c-83cd-003e6e90f74f
RITA -
used for the electronic collimation. Thus, high energy beta radiation can be detected with high resolution using a narrow collimator window. RITA Star is an extended version of MARITA that can measure
automatically many single traces one after the other. The RITA* detector is elevated after the end of the measurement and moved
automatically to the next trace position. Multi traces can be displayed as a 3-dimensional presentation or as a 2-dimensional distribution over the entire 200 x 200 mm TLC
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb
MiniGITA -
back compensates
automatically for the radioactive decay of the compound over the scan length. We provide different detectors and collimators to achieve the best performance according to the customer needs and application. For ß-nuclides we use... to the following trace and the next TLC can be examined. The chromatogram is displayed life on the screen of the connected PC. Peak integration and evaluation can be performed manually or
automatically. The measurement and data handing is digital
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354
Gabi * -
happen. Peak integration, background subtraction, flow correction, absolute activity calculation etc. can be performed manually or
automatically. Limit-of-detection is determined for every ROI, displayed and printed. GINA* and Clarity programs can
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915
Osmometer -
below the melting point. The stirring needle (vibrator)
automatically initiates crystallization. The crystallization warmth causes a temperature rise to the melting point (below 0°C). The temperature difference to 0°C measured is proportional to the
/en/cataloglight/osmometer~3b8829d9-bd1a-4af2-becd-10500bb70b84
MIRA Star -
flow cell to the following one is
automatically determined. When the delay of the 4 consequent flow detectors are digitally compensated, the 4 radio-chromatograms can be added up. This dramatically improve sensitivity and fractions which are not
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba
Endosafe -
and analysed against an internally-archived standard curve. By design, the PTS cartridge
automatically performs a duplicate sample/ duplicate positive product control LAL test, thereby satisfying the harmonized USP Bacterial Endotoxin Test (BET) and
/en/cataloglight/endosafe~5c1b4938-9e7f-4fd4-a5fe-fa402fa67635
MUCHA Nova -
calibration is obtained by using a suitable Cs-137 calibration source. Extended calibration through a suitable multi-nuclides source is also possible.Selected nuclides are named with the activity unit. Background spectra can be accumulated and
automatically
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c
PETra -
live on screen. No overriding of ranges can happen. Peak integration, background subtraction, flow correction, absolute activity calculation etc. can be performed manually or
automatically. Limit-of-detection is determined for every ROI, displayed
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b
ECOS -
. The selection valve features 1/16” fittings with 0.40 mm port , the entry port is connected to tubing coming from injector and flow is
automatically sent to the selected columns. The flow coming from the column is directed towards a manifold where
/en/cataloglight/ecos~b6aebf6f-4fa1-a8d9-ee95-39e9890b29ad
GINA X -
), quench correction or background subtraction make the difference compared to standard chromatography software. GINA X is also easier to take in hand. The software can record several chromatographic traces that can be manually or
automatically integrated
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d